| Radiator Cap | Pumping speed: 1 pump per second Standard valve (for brand-new cap): 93 to 123 kPa (1.0 to 1.3 kgf*cm2, 13.5 to 18 psi) Minimum standard valve (for used cap): 78.5 kPa (0.8 kgf*cm2, 11.4 psi) |
|
| Water inlet with thermostat | Valve opening temperature: 80 to 84°C (176 to 183°F) |
|
| Valve lift: 8.0 mm (0.315 in.) or more at 95°C (203°F) |
||
| Cooling fan motor | for 100W+100W Type | Standard current: 4.5 to 10.5 A at 20°C (68°F) (when the battery is connected to the fan motor connector) |
| for 200W+200W Type | Standard current: 13.0 to 19.0 A at 20°C (68°F) (when the battery is connected to the fan motor connector) |
|
| No. 2 cooling fan motor | for 100W+100W Type | Standard current: 4.5 to 10.5 A at 20°C (68°F) (when the battery is connected to the fan motor connector) |
| for 200W+200W Type | Standard current: 13.0 to 19.0 A at 20°C (68°F) (when the battery is connected to the fan motor connector) |
|
| Fan No. 1 relay | Standard resistance (3 - 5): 10 kΩ or higher (Battery voltage is not applied between terminals 1 and 2) Standard resistance (3 - 5): Below 1 Ω (Battery voltage is applied between terminals 1 and 2) |
|