FRONT PASSENGER AIRBAG ASSEMBLY REMOVAL


  1. PRECAUTION

    CAUTION:

    Be sure to read Precaution thoroughly before servicing Click here.

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.

  2. REMOVE NO. 1 INSTRUMENT PANEL GARNISH SUB-ASSEMBLY

    Click here

  3. DISCONNECT NO. 2 INSTRUMENT PANEL WIRE


    1. Check that the ignition switch is off.

    2. Check that the cable is disconnected from the negative (-) battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    3. A01EYKQE01
      Text in Illustration
      *a Slider

      Slide the slider to release the lock, and then disconnect the connector.

      Note

      When disconnecting any airbag connector, take care not to damage the airbag wire harness.

  4. REMOVE INSTRUMENT PANEL SAFETY PAD ASSEMBLY


    1. Disconnect each connector.

      A01EXGKE01
      Text in Illustration
      *A w/ Ion Generator - -
    2. Disengage each clamp.

    3. A01EXRN

      Disconnect the glove box light as shown in the illustration.

    4. Remove the 2 passenger airbag bolts <A>.

      A01ESPME01
      Text in Illustration
      *1 Passenger Airbag Bolt <A> *2 Bolt <B>
      *3 Nut <E> or <F> *4 Clip
    5. Remove the 3 bolts <B> and nut <E> or <F>.

    6. Remove the 2 clips.

    7. Disengage the 5 guides and remove the instrument panel safety pad assembly as shown in the illustration.

      A01EUYT

      Note


      • Do not damage the instrument panel safety pad assembly.

      • Do not allow the wire harnesses to interfere with the surrounding parts.

  5. REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY

    CAUTION:

    When storing the instrument panel passenger airbag assembly, keep the airbag deployment side facing upward.


    1. A01ETB5

      Remove the 2 screws.

    2. A01EWE6

      Lean the instrument panel safety pad assembly and disengage the 3 hooks.

    3. A01EWTV

      Disengage the 3 hooks to remove the instrument panel passenger airbag assembly from the instrument panel safety pad assembly.

  6. REMOVE NO. 2 INSTRUMENT PANEL WIRE


    1. A01EYBAE01
      Text in Illustration
      *1 Protective Tape
      *2 Airbag Connector
      *3 Airbag Connector Lock

      Disengage the clamp.

    2. Using a screwdriver with the tip wrapped with protective tape, release the airbag connector lock.

    3. Disconnect the airbag connector to remove the No. 2 instrument panel wire from the instrument panel passenger airbag assembly.

      Note

      When disconnecting any airbag connector, take care not to damage the airbag wire harness.