DESCRIPTION
The main body ECU (multiplex network body ECU) controls operation of the light cut relay in order to supply power to the interior lights. When battery saving control operates while the interior lights are on, the main body ECU (multiplex network body ECU) opens the light cut relay to turn off the lights.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK SYMPTOMS
Check symptoms.
| Result | Proceed to |
|---|---|
| All the interior lights that receive power via the light cut relay do not illuminate. | A |
| Battery saving function does not operate. | B |
| B |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER Click here |
| A |
|
INSPECT LIGHT CUT RELAY
Remove the light cut relay from the c1 light cut relay connector.
| *a | Component without harness connected (Light Cut Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE LIGHT CUT RELAY |
| OK |
|
CHECK HARNESS AND CONNECTOR (DOME FUSE - LIGHT CUT RELAY)
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (LIGHT CUT RELAY)
Install the light cut relay to the c1 light cut relay connector.
| *a | Component with harness connected (Light Cut Relay) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (LIGHT CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (LIGHT CUT RELAY - EACH LIGHT)
CHECK HARNESS AND CONNECTOR (LIGHT CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Remove the light cut relay from the c1 light cut relay connector.
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly Click here.
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Instrument panel junction block assembly) |
- | - |
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Active Test.
Check that the relay operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Relay for Interior Light Auto Cut Function | Light cut relay | ON/OFF | - |
| OK |
|---|
| Light auto cut relay operates. |
| NG |
|
INSPECT LIGHT CUT RELAY Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
INSPECT LIGHT CUT RELAY
Remove the light cut relay from the c1 light cut relay connector.
| *a | Component without harness connected (Light Cut Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE LIGHT CUT RELAY |
| OK |
|
CHECK HARNESS AND CONNECTOR (LIGHT CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly Click here.
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Instrument panel junction block assembly) |
- | - |
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here