INSTALL GENERATOR DRIVE END FRAME BEARING
Using SST and a press, install a new generator drive end frame bearing.
| *a | Tab |
| *b | Cutout |
Fit the tabs of the retainer plate into the cutouts of the generator drive end frame to install the retainer plate.
Install the 4 screws.
INSTALL GENERATOR ROTOR ASSEMBLY
Place the generator drive end frame on the generator pulley with clutch.
Install the generator rotor assembly to the generator drive end frame.
INSTALL GENERATOR COIL ASSEMBLY
| *a | Protrusion |
| *b | Groove |
Install a new bearing cover packing.
Note
Align the protrusions of the bearing cover packing with the grooves of the generator coil assembly when installing.
| *a | Deep Socket Wrench (21 mm) |
Using a 21 mm deep socket wrench and press, slowly press the generator coil assembly to install it.
Install the 4 bolts.
INSTALL GENERATOR BRUSH HOLDER ASSEMBLY
| *a | Pin (1.0 mm) |
While pushing the 2 brushes into the generator brush holder assembly, insert a 1.0 mm (0.0394 in.) pin into the generator brush holder assembly hole.
| *a | Pin |
Install the generator brush holder assembly to the generator coil assembly with the 2 screws.
Pull out the pin from the generator brush holder assembly hole.
INSTALL GENERATOR REAR END COVER
Install the generator terminal insulator to the generator coil assembly.
Note
Be sure to install the generator terminal insulator in the correct direction.
Install the generator rear end cover to the generator coil assembly with the 3 bolts.
INSTALL GENERATOR PULLEY WITH CLUTCH
Secure the generator assembly in a vise between aluminum plates.
Temporarily install the generator pulley with clutch to the rotor shaft.
| *a | Rotor Shaft |
Install SST (A) and (B) to the generator pulley with clutch as shown in the illustration.
| *a | Torque Wrench Fulcrum Length |
Tighten the generator pulley with clutch by turning SST (B) as shown in the illustration.
Note
Check that the generator assembly is secured in the vise tightly.
Hold SST (A) tightly during the operation.
Tech Tips
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench Click here.
When using SST (fulcrum length of 100 mm (3.94 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 57 N*m (581 kgf*cm, 42 ft.*lbf)
Remove SST (A) and (B) from the generator pulley with clutch.
Check that the generator pulley with clutch rotates smoothly.
Remove the generator assembly from the vise.
INSTALL GENERATOR PULLEY CAP
Install a new generator pulley cap to the generator pulley with clutch.