AUDIO AND VISUAL SYSTEM (for Radio Receiver Type) Sound Signal Circuit between Radio Receiver and Stereo Jack Adapter

DESCRIPTION

The No. 1 stereo jack adapter assembly sends the sound signal from an external device to the radio receiver assembly through this circuit.

The sound signal that has been sent is amplified by the radio receiver assembly, and then is sent to the speakers.

If there is an open or short in the circuit, sound cannot be heard from the speakers even if there is no malfunction in the radio receiver assembly or speakers.

WIRING DIAGRAM

A01ETPJE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (RADIO RECEIVER ASSEMBLY - NO. 1 STEREO JACK ADAPTER ASSEMBLY)


    1. Disconnect the No. 1 stereo jack adapter assembly and radio receiver assembly connectors.

    2. A01EVD5E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Radio Receiver Assembly)

      *b

      Front view of wire harness connector

      (to No. 1 Stereo Jack Adapter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I146-9 (AUXO) - I150-25 (AUXI) Always Below 1 Ω
      I146-6 (ARO) - I150-26 (ARI) Always Below 1 Ω
      I146-7 (ALO) - I150-28 (ALI) Always Below 1 Ω
      I146-8 (ASGN) - I150-27 (ASGN) Always Below 1 Ω
      I146-10 (AGND) - I150-11 (AGND) Always Below 1 Ω
      I146-2 (UDO-) - I151-2 (US1-) Always Below 1 Ω
      I146-3 (UDO+) - I151-3 (US1+) Always Below 1 Ω
      I146-5 (UJSS) - I151-5 (USG1) Always Below 1 Ω
      I146-9 (AUXO) - Body ground Always 10 kΩ or higher
      I146-6 (ARO) - Body ground Always 10 kΩ or higher
      I146-7 (ALO) - Body ground Always 10 kΩ or higher
      I146-8 (ASGN) - Body ground Always 10 kΩ or higher
      I146-10 (AGND) - Body ground Always 10 kΩ or higher
      I146-2 (UDO-) - Body ground Always 10 kΩ or higher
      I146-3 (UDO+) - Body ground Always 10 kΩ or higher
      I146-5 (UJSS) - Body ground Always 10 kΩ or higher

    NG