SHIFT LEVER INSPECTION


  1. INSPECT LOWER SHIFT LEVER ASSEMBLY (w/o Smart Entry and Start System)


    1. A01EXUNE01
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1 (ACC) - Body ground Ignition switch ON 11 to 14 V
      Ignition switch ACC 11 to 14 V
      Ignition switch off Below 1 V
      8 (STP) - Body ground Brake pedal depressed 11 to 14 V
      Brake pedal released Below 1 V
      5 (KLS+) - Body ground Ignition switch ACC and shift lever in P Below 1 V
      Ignition switch ACC and shift lever except in P (Within approx. 1 second) 7.5 to 11 V
      Ignition switch ACC and shift lever in P (After approx. 1 second) 6.0 to 9.5 V
      4 (IG) - Body ground Ignition switch ON 11 to 14 V
      Ignition switch off Below 1 V

      Tech Tips

      Do not disconnect the lower shift lever assembly connector.

    2. A01EXUNE02
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Value
      7 (E) - Body ground Always Below 1 Ω

      Tech Tips

      Do not disconnect the lower shift lever assembly connector.

    3. Inspect shift lock solenoid


      1. A01EUKZ

        Disconnect the shift lock solenoid connector.

      2. A01EXAJE09
        Text in Illustration
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

        Standard Resistance
        Tester Connection Shift Lever Position Specified Condition
        4 (P) - 3 (E2) P 10 kΩ or higher
        Other than P Below 1 Ω

        • If the result is not as specified, replace the lower shift lever assembly.

        • If the shift lock does not operate when the power source of the lower shift lever assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the lower shift lever assembly.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        • If the result is not as specified, replace the lower shift lever assembly.

        • If the shift lock does not operate when the power source of the lower shift lever assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the lower shift lever assembly.

  2. INSPECT LOWER SHIFT LEVER ASSEMBLY (w/ Smart Entry and Start System)


    1. A01EXTUE01
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      5 (IG) - Body ground Engine switch on (IG) 11 to 14 V
      Engine switch off Below 1 V
      4 (STP) - Body ground Brake pedal depressed 11 to 14 V
      Brake pedal released Below 1 V

      Tech Tips

      Do not disconnect the lower shift lever assembly connector.

    2. A01EXTUE02
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - Body ground Always Below 1 Ω

      Tech Tips

      Do not disconnect the lower shift lever assembly connector.

    3. Inspect shift lock solenoid


      1. A01EUKZ

        Disconnect the shift lock solenoid connector.

      2. A01EXAJE09
        Text in Illustration
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

        Standard Resistance
        Tester Connection Shift Lever Position Specified Condition
        4 (P) - 3 (E2) P 10 kΩ or higher
        Other than P Below 1 Ω

        • If the result is not as specified, replace the lower shift lever assembly.

        • If the shift lock does not operate when the power source of the lower shift lever assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the lower shift lever assembly.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        • If the result is not as specified, replace the lower shift lever assembly.

        • If the shift lock does not operate when the power source of the lower shift lever assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the lower shift lever assembly.

  3. INSPECT TRANSMISSION CONTROL SWITCH (for LHD)


    1. A01EV2FE09
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Control Switch)

      Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      3 (SFTU) - 2 (E)

      Shift lever held in "+"

      (Up-shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      1 (SFTD) - 2 (E)

      Shift lever held in "-"

      (Down-shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the resistance value is not as specified, replace the lower shift lever assembly.

  4. INSPECT TRANSMISSION CONTROL SWITCH (for RHD)


    1. A01EV2FE11
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Control Switch)

      Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      1 (SFTU) - 2 (E)

      Shift lever held in "+"

      (Up-shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      3 (SFTD) - 2 (E)

      Shift lever held in "-"

      (Down-shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the resistance value is not as specified, replace the lower shift lever assembly.