SHIFT LEVER INSPECTION


  1. INSPECT LOWER SHIFT LEVER ASSEMBLY


    1. A01EXTUE01
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      5 (IG) - Body ground Engine switch on (IG) 11 to 14 V
      Engine switch off Below 1 V
      4 (STP) - Body ground Brake pedal depressed 11 to 14 V
      Brake pedal released Below 1 V

      Tech Tips

      Do not disconnect the shift lock control unit assembly connector.

    2. A01EXTUE02
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - Body ground Always Below 1 Ω

      Tech Tips

      Do not disconnect the shift lock control unit assembly connector.

    3. Inspect shift lock solenoid


      1. A01EUKZ

        Disconnect the shift lock solenoid connector.

      2. A01EXAJE09
        Text in Illustration
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

        Standard Resistance
        Tester Connection Shift Lever Position Specified Condition
        4 (P) - 3 (E2) P 10 kΩ or higher
        4 (P) - 3 (E2) Other than P Below 1 Ω

        • If the result is not as specified, replace the shift lock control unit assembly.

        • If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        • If the result is not as specified, replace the shift lock control unit assembly.

        • If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

  2. INSPECT TRANSMISSION CONTROL SWITCH


    1. A01EV2FE08
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Control Switch)

      Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      3 (SFTU) - 2 (E)

      Shift lever held in "+"

      (Up-shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      1 (SFTD) - 2 (E)

      Shift lever held in "-"

      (Down-shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the resistance value is not as specified, replace the shift lock control unit assembly.