Using a vacuum pump, apply 80 kPa (600 mmHg, 23.6 in.Hg) or higher of vacuum to the vacuum tank. Wait for 1 minute and check that the needle of the vacuum pump does not lower.
If the result is not as specified, replace the air cleaner cap sub-assembly.