COMPRESSOR (for 2GR-FE) INSPECTION


  1. INSPECT COOLER COMPRESSOR ASSEMBLY (A/C LOCK SENSOR)


    1. A01EWNRE42
      Text in Illustration
      *a

      Component without harness connected

      (Cooler Compressor Assembly (A/C Lock Sensor))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E73-1 (SSR+)- E73-2 (SSR-) 20°C (68°F) 160 to 320 Ω

      If the resistance is not as specified, replace the cooler compressor assembly.

  2. INSPECT COOLER COMPRESSOR ASSEMBLY (COMPRESSOR SOLENOID)


    1. A01EU5XE03
      Text in Illustration
      *a

      Component without harness connected

      (Cooler Compressor Assembly (Compressor Solenoid))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E74-1 (SOL-) - E74-2 (SOL+) 20°C (68°F) 10 to 11 Ω

      If the resistance is not as specified, replace the cooler compressor assembly.

  3. INSPECT COOLER COMPRESSOR ASSEMBLY


    1. Disconnect the E73 cooler compressor assembly connector.

    2. A01EW3IE03
      Text in Illustration
      *a

      Component without harness connected

      (Cooler Compressor Assembly)

      *b

      Component without harness connected

      (Magnetic Clutch Assembly)

      Disconnect the a2 magnetic clutch assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E73-3 (MG+) - a2-1 Always Below 1 Ω
      E73-3 (MG+) - Body ground Always 10 kΩ or higher

      If the resistance is not as specified, replace the cooler compressor assembly.