2GR-FE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 7.7 mm (0.3031 in.) or more at 95°C (203°F)
COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 7.3 to 9.3 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 7.3 to 9.3 A
COOLING FAN RELAY
Item Tester Connection Specified Condition
Fan relay 3 - 5

10 kΩor higher

(Battery voltage is not applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(Battery voltage is applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap

Standard value

(for brand-new cap)

93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)

Minimum standard value

(for used cap)

78.5 kPa (0.8 kgf/cm2, 11.4 psi)