HEATED OXYGEN SENSOR INSPECTION


  1. INSPECT HEATED OXYGEN SENSOR


    1. A01EZ0PE05
      Text in Illustration
      *a

      Component without harness connected

      (Heated Oxygen Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E21-1 (HT1B) - E21-2 (+B) 20°C (68°F) 9 to 14 Ω
      E21-1 (HT1B) - E21-4 (E2) Always 10 kΩ or higher

      If the result is not as specified, replace the heated oxygen sensor.