KNOCK SENSOR INSTALLATION


  1. INSTALL KNOCK CONTROL SENSOR


    1. A01EX4TE09
      Text in Illustration
      *a Front of Engine
      *b Up
      *c 10°
      *d 10°

      Install the knock control sensor with the bolt so that the knock control sensor is positioned as shown in the illustration.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }

      Note

      The acceptable installation angle of the knock control sensor is between 10° upward and 10° downward from the horizontal position.

    2. Connect the knock control sensor connector.

  2. INSTALL INTAKE MANIFOLD

    Click here