ECM INSTALLATION


  1. INSTALL ECM


    1. Install the No. 1 ECM bracket and No. 2 ECM bracket to the ECM with the 4 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    2. Install the ECM with the 2 nuts.

      Torque:
      12 N*m  { 122 kgf*cm, 9 ft.*lbf }
    3. A01EW9R

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the connectors, make sure that dirt, water or other foreign matter is not stuck between the connectors and connecting part of the ECM.

      • Make sure that the 2 levers are securely locked.

  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. PERFORM INITIALIZATION

    Click here