INSTALL NO. 1 ECM BRACKET
Install the ECM bracket with the nut.
Connect the wire harness clamp.
Connect the wire harness clamp.
Install the nut.
INSTALL ECM
Install the ECM brackets to the ECM with the 2 screws.
Temporarily install the screw (B).
Install the ECM with the nut.
Install the screw (A).
Tighten the screw (B).
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the connectors, make sure that dirt, water or other foreign matter does not become stuck between the connectors and other part.
Make sure that the 2 levers are securely locked.
Connect the 2 wire harness clamps.
INSTALL BATTERY
Install the battery and battery tray.
Install the battery clamp with the bolt and nut.
Connect the positive (+) battery terminal
INSTALL COOL AIR INTAKE DUCT SEAL
Install the cool air intake duct seal with the 9 clips.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
PERFORM INITIALIZATION