PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Note
Do not apply positive (+) battery voltage to any terminals other than terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
When a power window regulator or a power window regulator motor assembly is replaced, the power window control system must be initialized Click here.
| *1 | Motor Gear |
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
Check the motor gear rotates smoothly as follows.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 |
Motor gear rotates clockwise |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 |
Motor gear rotates counterclockwise |
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
Note
Do not apply positive (+) battery voltage to any terminals other than terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
When a power window regulator or a power window regulator motor assembly is replaced, the power window control system must be initialized Click here.
| *1 | Motor Gear |
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Counterclockwise |
| *c | Clockwise |
Check the motor gear rotates smoothly as follows.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 |
Motor gear rotates clockwise |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 |
Motor gear rotates counterclockwise |