AIR CONDITIONING PANEL(for Automatic Air Conditioning System) INSPECTION

PROCEDURE


  1. INSPECT AIR CONDITIONER CONTROL ASSEMBLY

    A005IOOE02
    Text in Illustration
    *a

    Component without harness connected

    (Air Conditioner Control Assembly)


    1. Apply battery voltage to the connector and check the illumination condition.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 6

      Battery negative (-) → 8

      Illumination comes on