PROCEDURE
INSPECT AIR CONDITIONER PRESSURE SENSOR (for Manual Air Conditioning System)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Check the wire harness.
Disconnect the connector of the air conditioner pressure sensor.
Using an ohmmeter, measure the resistance of the wire harness side connector.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch to ON.
Measure the voltage of the wire harness side connector.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Check the air conditioner pressure sensor.
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
| *b | Voltage (V) |
| *c | MPa |
| *d | kgf/cm2 |
| *e | psi |
| *f | Refrigerant Pressure |
Set the manifold gauge.
Connect the connector to the air conditioner pressure sensor.
Warm up the engine.
Switch A/C ON.
Using a voltmeter, measure the voltage between connector terminals 7 (PRE) and 5 (SG-2) of the air conditioning amplifier assembly.
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
INSPECT AIR CONDITIONER PRESSURE SENSOR (for Automatic Air Conditioning System)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Check the wire harness.
Disconnect the connector of the air conditioner pressure sensor.
Using an ohmmeter, measure the resistance of the wire harness side connector.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch to ON.
Measure the voltage of the wire harness side connector.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Check the air conditioner pressure sensor.
Set the manifold gauge.
Connect the connector to the air conditioner pressure sensor.
Warm up the engine.
Switch A/C ON.
Using a voltmeter, measure the voltage between connector terminals 9 (PRE) and 13 (SG-2) of the air conditioning amplifier assembly.
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
| *b | Voltage (V) |
| *c | MPa |
| *d | kgf/cm2 |
| *e | psi |
| *f | Refrigerant Pressure |