SOLAR SENSOR INSPECTION

PROCEDURE


  1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR


    1. A005I86E01
      Text in Illustration
      *a

      Component with harness connected:

      (Automatic Light Control Sensor)

      Check the voltage.


      1. Connect the solar sensor connector.

      2. Turn the ignition switch to ON.

      3. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        F73 - 1 (TSD) - F73 - 5 (CLTE) Without direct light exposure (Sensor covered) Below 0.8 V
        When exposed to sunlight or an inspection light 4.0 to 4.6 V

        Note

        Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the automatic light control sensor.


        • If the result is not as specified, replace the automatic light control sensor.