AIR CONDITIONING SYSTEM(for Manual Air Conditioning System), Diagnostic DTC:B1413

DTC Code DTC Name
B1413 Evaporator Temperature Sensor Circuit

DESCRIPTION

The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.

DTC No. DTC Detection Condition Trouble Area
B1413 An open or short in the No. 1 cooler thermistor circuit.
  • No. 1 cooler thermistor

  • Harness or connector

  • Air conditioning amplifier assembly

WIRING DIAGRAM

A005IP0E03
*a NO. 1 COOLER THERMISTOR
*b AIR CONDITIONING AMPLIFIER ASSEMBLY

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (NO. 1 COOLER THERMISTOR)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. According to the display on the intelligent tester, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Evaporator Fin Thermistor

      No. 1 cooler thermistor /

      Min.: -29.7°C (-21.5°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.5°F)

      Short in the circuit: 59.55°C (139.19°F)

      OK
      The display is as specified in the normal condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to the DTC) A
      OK (When troubleshooting according to problem symptoms table) B
      NG C

    B
    C
    A
  2. CHECK FOR DTC


    1. Clear the DTCs Click here.

    2. Check for DTCs Click here.

      OK
      DTC B1413 is not output

    OK
    NG
  3. INSPECT NO. 1 COOLER THERMISTOR


    1. Remove the No. 1 cooler thermistor Click here.

    2. Inspect the No. 1 cooler thermistor Click here.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR


    1. Disconnect the F41 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      F32-1 - F41-15 (SG-1) Always Below 1 Ω
      A24-1 - F41-4 (TE) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      F32-1 - Body ground Always 10 kΩ or higher
      F32-2 - Body ground Always 10 kΩ or higher

    OK
    NG