AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) PRECAUTION


  1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME

    A005KCD
  2. ALWAYS WEAR EYE PROTECTION

  3. BE CAREFUL NOT TO GET LIQUID REFRIGERANT IN YOUR EYES OR ON YOUR SKIN

    A005K3J

    If liquid refrigerant gets in your eyes or on your skin:


    1. Wash the area with lots of cold water.

      CAUTION:

      Do not rub your eyes or skin.

    2. Apply clean petroleum jelly to the skin.

    3. Go immediately to a hospital or see a physician for professional treatment.

  4. NEVER HEAT CONTAINER OR EXPOSE THE CONTAINER TO OPEN FLAME

  5. BE CAREFUL NOT TO DROP CONTAINER OR APPLY PHYSICAL SHOCKS TO IT

  6. DO NOT OPERATE COMPRESSOR WITHOUT ENOUGH REFRIGERANT IN REFRIGERANT SYSTEM

    If there is not enough refrigerant in the air conditioning system, the oil lubrication will be insufficient and the compressor may be damaged.

    Necessary care should be taken to avoid this.

  7. DO NOT OPEN HIGH PRESSURE MANIFOLD VALVE WHILE COMPRESSOR IS OPERATING

    A005M9EE31
    Text in Illustration
    *a Incorrect
    *b Correct

    Open and close only the low pressure valve. Opening and closing the high pressure valve could cause the charging cylinder to rupture.

  8. BE CAREFUL NOT TO OVERCHARGE SYSTEM WITH REFRIGERANT

    If the refrigerant is overcharged, it causes problems such as insufficient cooling, poor fuel economy, engine overheating, etc.

  9. DO NOT OPERATE ENGINE AND COMPRESSOR WITH NO REFRIGERANT

    Note

    Doing so may damage the inside of the compressor because the compressor parts move regardless of whether the air conditioning system is turned on or off.