GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  3. REMOVE ENGINE UNDER COVER RH

    Click here

  4. REMOVE FAN AND GENERATOR V BELT

    Click here

  5. REMOVE GENERATOR ASSEMBLY

    A005JEXE01

    1. Remove the terminal cap.

    2. Disconnect the connector and the harness clamp.

    3. Remove the nut and disconnect the wire harness from terminal B.

      Text in Illustration
      *1 Terminal B
    4. A005GT5E01

      Remove the belt adjusting slider fixing bolt A, nut B and remove the belt adjusting slider.

    5. A005I0KE02

      Remove the bolt A, screw B and the piping clamp.

    6. A005JPQ