PROCEDURE
INSTALL GENERATOR DRIVE END FRAME BEARING
Using SST and a press, press in a new generator drive end frame bearing.
| *1 | Tab |
| *2 | Cutout |
Fit the tabs of the bearing retainer into the cutouts on the generator drive end frame assembly to install the bearing retainer.
Install the 4 screws.
INSTALL GENERATOR ROTOR ASSEMBLY
Place the drive end frame on the generator clutch pulley.
Install the generator rotor assembly onto the generator drive end frame.
INSTALL GENERATOR COIL ASSEMBLY
Install a new bearing cover packing on the generator coil assembly.
Using SST and a press, slowly press in the generator coil assembly.
Install the 4 bolts.
INSTALL GENERATOR BRUSH HOLDER ASSEMBLY
| *1 | Pin (1.0 mm (0.0394 in.)) diameter |
While pushing the 2 brushes into the generator brush holder assembly, insert a 1.0 mm (0.0394 in.) diameter pin into the brush holder hole.
Install the brush holder assembly to the generator coil assembly with the 2 screws.
| *1 | Pin (1.0 mm (0.0394 in.)) diameter |
Pull out the pin from the generator brush holder assembly.
INSTALL GENERATOR TERMINAL INSULATOR
Install the generator terminal insulator to the generator coil assembly.
Note
Be sure to install the generator terminal insulator as shown in the illustration.
INSTALL GENERATOR REAR END COVER
Install the generator rear end cover onto the generator coil assembly with the 3 bolts.
INSTALL GENERATOR CLUTCH PULLEY
Temporarily install the generator clutch pulley onto the rotor shaft.
Clamp the generator drive end frame in a vise tightly.
| *1 | Rotor Shaft |
Place the rotor shaft end into SST (A).
| *1 | Generator Clutch Pulley |
Fit SST (B) to the generator clutch pulley.
| *a | Hold |
| *b | Turn |
| *c | Length 100 mm |
| *d | Length 318 mm |
Tighten the pulley by turning SST (B) in the direction shown in the illustration.
Note
Check that the generator drive end frame is secured in the vise tightly.
Hold SST (A) tightly during the operation.
Tech Tips
Use a torque wrench with a fulcrum length of 318 mm (12.52 in.).
This torque value is effective when SST 100 mm (5.12 in.) is parallel to the torque wrench.
Remove SST from the generator assembly.
Check that the clutch pulley rotates smoothly.
INSTALL GENERATOR PULLEY CAP
Install a new generator pulley cap onto the generator clutch pulley.