MULTI-MODE MANUAL TRANSAXLE SYSTEM TC and CG Terminal Circuit

DESCRIPTION

Terminals TC and CG are located in the DLC3. When performing [Initialization and Learning] without using an intelligent tester, connecting terminals TC and CG is necessary. If the TC terminal circuit is open, these calibration procedures cannot be performed without using an intelligent tester.

WIRING DIAGRAM

A005LQ9E03

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (TCM - DLC3)


    1. Disconnect the F68 TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F68-25 (DG) - F4-13 (TC) Always Below 1 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TC OF DLC3 - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F4-13 (TC) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (CG OF DLC3 - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F4-4 (CG) - Body ground Always Below 1 Ω

    NG
    OK
  4. REPLACE TCM


    1. Replace the TCM Click here.


    NEXT
  5. PERFORM INITIALIZATION


    1. Perform the initialization and learning for multi-mode manual transaxle system Click here.


    NEXT