SELECT STROKE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL SELECT STROKE SENSOR


    1. Apply MP grease to a new O-ring.

    2. Install the new O-ring onto the select stroke sensor.

    3. A005MB7E02
      Text in Illustration
      *a Sensor Arm (Actuator Side)
      *b Sensor Arm (Sensor Side)

      Set the select stroke sensor so that the sensor side and the actuator side sensor arms are in the positions shown in the illustration.

    4. Turn the select stroke sensor clockwise and fix it with the 2 screws.

      Torque:
      1.3 N*m  { 13 kgf*cm, 12 in.*lbf }
    5. Install the wire harness and connect the connectors.

  2. INSTALL SHIFT AND SELECT ACTUATOR ASSEMBLY

    Click here