SELECT STROKE SENSOR INSPECTION

PROCEDURE


  1. INSPECT SELECT STROKE SENSOR

    A005M27E01
    Text in Illustration
    *a

    Component without harness connected

    (Select Stroke Sensor)

    *b Main
    *c Sub
    *d Sensor Arm

    1. Connect 3 dry batteries of 1.5 V in series.

    2. Connect the battery positive (+) lead to terminal A and the negative (-) lead to terminal B.

    3. Turn the sensor arm and check the voltage between terminals B and C.

      Reference
      Voltage (Power Source Voltage at 4.5 V)
      Sensor Angle Terminal (B - C) Output Voltage
      55 ° 4.05 V
      2.25 V
      -55° 0.45 V
      Voltage (Power Source Voltage at 4.7 to 5.3 V)
      Sensor Angle Terminal (B - C) Output Voltage
      55 ° 4.5 V
      2.5 V
      -55° 0.5 V

      Note


      • Do not apply more than 6 V.

      • Do not drop the clutch stroke sensor. If dropped, replace it with a new one.

      If the voltage is not as specified, replace the stroke sensor.