OIL PUMP INSPECTION

PROCEDURE


  1. INSPECT OIL PUMP DRIVE AND DRIVEN ROTORS

    A005IVXE02
    Text in Illustration
    *1 Feeler Gauge

    1. Check the tip clearance.


      1. Using a feeler gauge, measure the clearance between the tips of the drive rotor and driven rotor.

        Standard tip clearance
        0.08 to 0.16 mm (0.0031 to 0.0063 in.)
        Maximum tip clearance
        0.21 mm (0.0083 in.)

        If the tip clearance is greater than the maximum, replace the oil pump.

    2. A005LDLE01
      Text in Illustration
      *1 Feeler Gauge

      Check the body clearance.


      1. Using a feeler gauge, measure the clearance between the driven rotor and oil pump body.

        Standard body clearance
        0.10 to 0.18 mm (0.0039 to 0.0071 in.)
        Maximum body clearance
        0.20 mm (0.0079 in.)

        If the body clearance is greater than the maximum, replace the oil pump.

    3. A005L4TE01
      Text in Illustration
      *1 Feeler Gauge
      *2 Steel Square

      Check the side clearance.


      1. Using a feeler gauge and steel square, measure the clearance between the rotors and steel square.

        Standard side clearance
        0.03 to 0.09 mm (0.0012 to 0.0035 in.)
        Maximum side clearance
        0.15 mm (0.0059 in.)

        If the side clearance is greater than the maximum, replace the oil pump.