PROCEDURE
INSPECT THERMOSTAT
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature of the thermostat.
| Valve opening temperature |
|---|
| 86 to 90°C (187 to 194°F) |
If the valve opening temperature is not as specified, replace the thermostat.
| *a | Valve Lift |
Check the valve lift.
| Valve lift |
|---|
| 8.5 mm (0.335 in.) or more at 100°C (212°F) |
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at low temperatures (below 83°C (181°F))
If not fully closed, replace the thermostat.