RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT FAN NO. 1 RELAY

    A005IWW

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the FAN No. 1 relay.

  2. INSPECT FAN NO. 2 RELAY

    A005K23E16

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage not applied Below 1 Ω
      Battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage not applied 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the FAN No. 2 relay.