PROCEDURE
INSPECT FUEL PUMP
| *a | Component without harness connected (Fuel Pump) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the fuel pump.
Check fuel pump operation.
Connect the positive (+) lead of the battery to terminal 1 of the connector and the negative (-) lead to terminal 2. Check that the fuel pump operates.
Note
This test must be done quickly (within 10 seconds) to prevent the coil from burning out.
Keep the fuel pump as far away from the battery as possible.
Always switch the voltage on and off at the battery, not the fuel pump.
If the pump does not operate, replace the fuel pump.