SFI SYSTEM, Diagnostic DTC:P0403

DTC Code DTC Name
P0403 Exhaust Gas Recirculation Control Circuit

DESCRIPTION

The ECM lowers combustion chamber temperatures and reduces Nitrogen Oxide (NOx) emissions by recirculating an appropriate amount of exhaust gas to the combustion chambers according to the engine operating conditions. When all EGR activation conditions are met (based on sensor signals such as engine speed, coolant temperature, load signal, vehicle speed signal), the ECM turns on the stepper motor inside the EGR valve and linearly controls the opening angle of the EGR valve. When the ECM determines that EGR operation will not influence engine operating conditions, the ECM forcibly opens and closes the EGR valve to monitor changes in manifold pressure. If the manifold pressure change is less than that during normal EGR valve operation, the ECM will detect a shortage of EGR gas flow and set a DTC. Also, an EGR DTC is set if a malfunction (open or short circuit) occurs in the EGR valve operation circuit.

DTC No. DTC Detection Condition Trouble Area
P0403

Both of the following conditions are met for 1 second or more (1 trip detection logic):


  1. The engine is running.

  2. When any of terminals EGR1 to 4 has a fixed voltage of 0 V.


  • Open or short in EGR circuit

  • EGR valve assembly

  • ECM

MONITOR DESCRIPTION

This DTC is designed to detect an open or short is the EGR valve circuit.

If the EGR terminal voltage is low when the EGR terminal output is off, the ECM determines that the EGR valve circuit is malfunctioning.

CONFIRMATION DRIVING PATTERN

A005KEVE05

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON and turn the tester on [A].

  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure) Click here.

  4. Start the engine and warm it up [B].

  5. Drive the vehicle at 20 km/h (12 mph) or more for 10 minutes [C].

    CAUTION:

    When performing the confirmation driving pattern, obey all speed limits and traffic laws.

  6. Enter the following menus: Powertrain / Engine and ECT / DTC [D].

  7. Read the pending DTCs.

    Tech Tips


    • If a pending DTC is output, the system is malfunctioning.

    • If a pending DTC is not output, perform the following procedure.

  8. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  9. Input the DTC: P0403.

  10. Check the DTC judgment result.

    Tester Display Description
    NORMAL
    • DTC judgment completed

    • System normal

    ABNORMAL
    • DTC judgment completed

    • System abnormal

    INCOMPLETE
    • DTC judgment not completed

    • Perform driving pattern after confirming DTC enabling conditions

    UNKNOWN
    • Unable to perform DTC judgment

    • Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    Tech Tips


    • If the judgment result shows NORMAL, the system is normal.

    • If the judgment result shows ABNORMAL, the system has a malfunction.

WIRING DIAGRAM

A005J1NE01

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE


  1. INSPECT EGR VALVE ASSEMBLY


    1. A005H4PE06
      Text in Illustration
      *a

      Component without harness connected

      (EGR Valve Assembly)

      Disconnect the EGR valve assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      5 (+B2) - 4 (EGR1) 20°C (68°F) 18 to 22 Ω
      5 (+B2) - 6 (EGR3) 20°C (68°F) 18 to 22 Ω
      2 (+B1) - 3 (EGR2) 20°C (68°F) 18 to 22 Ω
      2 (+B1) - 1 (EGR4) 20°C (68°F) 18 to 22 Ω
    3. Reconnect the EGR valve assembly connector.


    NG
    OK
  2. INSPECT EGR VALVE ASSEMBLY (VOLTAGE)


    1. A005HYYE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to EGR Valve Assembly)

      Disconnect the EGR valve assembly connector.

    2. Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      B56-2 (+B1) - Body ground Ignition switch ON 11 to 14 V
      B56-5 (+B2) - Body ground Ignition switch ON 11 to 14 V
    4. Reconnect the EGR valve assembly connector.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (EGR VALVE ASSEMBLY - ECM)


    1. Disconnect the EGR valve assembly connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      B56-4 (EGR1) - B23-28 (EGR1) Always Below 1 Ω
      B56-3 (EGR2) - B23-27 (EGR2) Always Below 1 Ω
      B56-6 (EGR3) - B23-26 (EGR3) Always Below 1 Ω
      B56-1 (EGR4) - B23-25 (EGR4) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      B56-4 (EGR1) or B23-28 (EGR1) - Body ground Always 10 kΩ or higher
      B56-3 (EGR2) or B23-27 (EGR2) - Body ground Always 10 kΩ or higher
      B56-6 (EGR3) or B23-26 (EGR3) - Body ground Always 10 kΩ or higher
      B56-1 (EGR4) or B23-25 (EGR4) - Body ground Always 10 kΩ or higher
    4. Reconnect the EGR valve assembly connector.

    5. Reconnect the ECM connector.


    OK
    NG
  4. CHECK HARNESS AND CONNECTOR (EGR VALVE ASSEMBLY - NO. 1 INTEGRATION RELAY)


    1. Disconnect the EGR valve assembly connector.

    2. Remove the No. 1 integration relay from the engine room main relay block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      B56-2 (+B1) - 1E-4 Always Below 1 Ω
      B56-5 (+B2) - 1E-4 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      B56-2 (+B1) or 1E-4 - Body ground Always 10 kΩ or higher
      B56-5 (+B2) or 1E-4 - Body ground Always 10 kΩ or higher
    4. Reconnect the EGR valve assembly connector.

    5. Reinstall the No. 1 integration relay.


    OK
    NG