SFI SYSTEM Starter Signal Circuit

DESCRIPTION


WIRING DIAGRAM

A005L16E03

CAUTION / NOTICE / HINT

Tech Tips

This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to the problem symptoms table Click here.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the tester on.

    4. Enter the following menu items: Powertrain / Engine and ECT / Data List / Starter Signal.

    5. Read the value.

      OK
      Ignition Switch Position Starter Signal
      ON OFF
      START ON

    OK
    NG
  2. CHECK ST RELAY (POWER SOURCE)


    1. A005HVRE07
      Text in Illustration
      *1 Engine Room Main Relay Block
      *2 ST Relay Holder

      Remove the ST relay from the engine room main relay block.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      ST relay terminal 2 - Body ground Engine cranking 11 to 14 V

      Tech Tips

      The engine does not crank because the relay is not installed.

    3. Reinstall the ST relay.


    NG
    OK
  3. INSPECT ST RELAY


    1. Inspect the ST relay Click here.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (ST RELAY - BODY GROUND)


    1. Remove the ST relay from the engine room main relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      ST relay terminal 1 - Body ground Always Below 1 Ω
    3. Reinstall the ST relay.


    OK
    NG
  5. CHECK HARNESS AND CONNECTOR (ST RELAY - PARK/NEUTRAL POSITION SWITCH ASSEMBLY)


    1. Remove the ST relay from the engine room main relay block.

    2. Disconnect the park/neutral position switch assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      ST relay terminal 2 - B69-9 (L) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      ST relay terminal 2 or B69-9 (L) - Body ground Always 10 kΩ or higher
    4. Reinstall the ST relay.

    5. Reconnect the park/neutral position switch assembly connector.


    NG
    OK
  6. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY


    1. Inspect the park/neutral position switch assembly Click here.


    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - IGNITION SWITCH)


    1. Disconnect the park/neutral position switch assembly connector.

    2. Disconnect the ignition switch assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      B69-4 (B) - F13-7 (ST2) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      B69-4 (B) or F13-7 (ST2) - Body ground Always 10 kΩ or higher
    4. Reconnect the park/neutral position switch assembly connector.

    5. Reconnect the ignition switch assembly connector.


    NG
    OK
  8. INSPECT IGNITION SWITCH ASSEMBLY


    1. Inspect the ignition switch assembly Click here.


    OK
    NG