INTEGRATION RELAY INSPECTION

PROCEDURE


  1. INSPECT NO. 1 INTEGRATION RELAY


    1. Check the EFI MAIN relay.


      1. A005ILWE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1C-1 - 1E-4 Battery voltage is not applied to terminals 1E-10 and 1D-7 10 kΩ or higher
        Battery voltage is applied to terminals 1E-10 and 1D-7 Below 1 Ω

        If the result is not as specified, replace the EFI MAIN relay.

    2. Check the C/OPN relay.


      1. A005ILWE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1E-4 - 1E-5 Battery voltage is not applied to terminals 1E-11 and 1D-9 10 kΩ or higher
        Battery voltage is applied to terminals 1E-11 and 1D-9 Below 1 Ω

        If the result is not as specified, replace the C/OPN relay.

    3. Check the IG2 relay.


      1. A005ILWE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1C-1 - 1E-2 Battery voltage is not applied to terminals 1E-10 and 1D-17 10 kΩ or higher
        Battery voltage is applied to terminals 1E-10 and 1D-17 Below 1 Ω

        If the result is not as specified, replace the IG2 relay.

    4. Check the HORN relay.


      1. A005ILWE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1C-1 - 1E-7 Battery voltage is not applied to terminals 1C-1 and 1D-18 10 kΩ or higher
        Battery voltage is applied to terminals 1C-1 and 1D-18 Below 1 Ω

        If the result is not as specified, replace the HORN relay.