HEATED OXYGEN SENSOR INSTALLATION

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. A005L36E02
      Text in Illustration
      *a Fulcrum Length 300mm
      *b Fulcrum Length 30mm

      Using SST, install the heated oxygen sensor.

      SST
      09224-00010
      Torque:
      without SST
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
      with SST
      40 N*m  { 408 kgf*cm, 30 ft.*lbf }

      Tech Tips


      • The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).

      • The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.) Click here.

      • This torque value is effective when SST is parallel to the torque wrench.

    2. Connect the heated oxygen sensor connector.

    3. Install the wire harness to the wire harness bracket.

  2. INSPECT FOR EXHAUST GAS LEAK