| Thermostat | Opening temperature | 80 to 84°C (176 to 183°F) | ||
| Lift | 8.5 mm (0.33 in.) at 95°C (203°F) | |||
| Cooling fan motor | 1(-) - 2(+) | 11.2 to 14.4 A at 20°C (68°F) | ||
| Radiator cap sub-assembly | Standard valve (for brand new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
||
| Minimum standard valve (after using cap) | 78.5 kPa (0.80 kgf/cm2, 11.38 psi) |
|||
| Cooling fan resistor | 1 - 2 | 1.17 to 1.43 Ω at 20°C (68°F) | ||
| Cooling fan relay | 3 - 5 | 10 kΩ or higher (Battery voltage not applied) | ||
| 3 - 5 | Below 1 Ω (Battery voltage applied to terminals 1 and 2) | |||
| No. 2 Cooling fan relay | 3 - 4 | Below 1 Ω (Battery voltage not applied) | ||
| 3 - 4 | 10 kΩ or higher (Battery voltage applied to terminals 1 and 2) | |||
| 3 - 5 | 10 kΩ or higher (Battery voltage not applied) | |||
| 3 - 5 | Below 1 Ω (Battery voltage applied to terminals 1 and 2) | |||