PROCEDURE
INSPECT AUTOMATIC LIGHT CONTROL SENSOR
Disconnect the automatic light control sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (CLTS) - 5 (CLTE) | Ignition switch off | Below 1 V |
| Ignition switch on | 11 to 14 V |
| *a | Component with harness connected (to Automatic Light Control Sensor) |
If the result is not as specified, repair or replace the wire harness or connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 5 (CLTE) -Body ground | Below 1 V |
If the result is not as specified, repair or replace the wire harness or connector.
Reconnect the automatic light control sensor connector.
| *a | Rear view of wire harness connector (to Automatic Light Control Sensor) |
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.
| OK | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, replace the automatic light control sensor.