PROCEDURE
INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP
Note
If reusing the clips, do not remove the double sided tape remaining on the clips and where the clips will be installed on the body.
If installing new clips, remove the double-sided tape remaining where the clips will be installed on the body and clean the body with a non-residue solvent.
| *1 | Adhesive |
| *a | 2 to 3 mm Bead of Adhesive |
Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to new roof drip side finish moulding clips.
Tech Tips
Adhesive strength (tensile strength): 13.7 Mpa (140 kgf/cm2, 1987 psi) or more when the temperature is 23°C (73°F)
Install new 2 clips in the positions as shown in the illustration. Press in the clips by hand (except Glass Roof).
| Specification | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
After pressing in the clips, wait 30 minutes or more before installing the roof drip side finish moulding.
Tech Tips
Minimum hardening time: 30 minutes
Time needed for complete hardening: 24 hours
Install new 2 clips in the positions as shown in the illustration. Press in the clips by hand (for Glass Roof).
| Specification | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
After pressing in the clips, wait 30 minutes or more before installing the roof drip side finish moulding.
Tech Tips
Minimum hardening time: 30 minutes
Time needed for complete hardening: 24 hours
INSTALL ROOF DRIP SIDE FINISH MOULDING (except Glass Roof)
Engage the 2 clips and install the roof drip side finish moulding.
Remove the protective tape.
INSTALL ROOF DRIP SIDE FINISH MOULDING (for Glass Roof)
Engage the 2 clips and install the roof drip side finish moulding.
Remove the protective tape.