LIGHTING SYSTEM Stop Light Circuit

DESCRIPTION

When the stop light switch is turned on, current flows to the stop lights to illuminate them.

WIRING DIAGRAM

A005LD4E04

CAUTION / NOTICE / HINT

Note

Inspect the fuses and bulbs for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. INSPECT STOP LIGHT SWITCH ASSEMBLY


    1. Remove the stop light switch assembly Click here.

    2. Inspect the stop light switch assembly Click here.


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (BATTERY - STOP LIGHT SWITCH ASSEMBLY)


    1. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A37-2 - Body ground Always 11 to 14 V

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - BATTERY, STOP LIGHT SWITCH)


    1. Remove the No. 1 integration relay Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      A37-1 - 1D-2 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      A37-1 - Body ground Always 10 kΩ or higher
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1E-6 - Body ground Always 11 to 14 V

    OK
    NG