РЫЧАГ ПЕРЕКЛЮЧЕНИЯ ПЕРЕДАЧ ПРОВЕРКА

Информация добавлена 08-08-2017

PROCEDURE


  1. INSPECT SHIFT LOCK CONTROL ECU


    1. Disconnect the shift lock solenoid connector from the shift lock control ECU.

    2. A01A35AC04
      *a

      Component without harness connected

      (Shift Lock Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Tech Tips

      Do not disconnect the shift lock control ECU connector.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1 (SLS+) - 2 (SLS-) Engine switch off Below 1 V
      1 (SLS+) - 2 (SLS-) Engine switch on (IG) Below 1 V
      Engine switch on (IG) and brake pedal depressed 11 to 14 V

      If the result is not as specified, replace the shift lock control ECU.

  2. INSPECT SHIFT LOCK SOLENOID


    1. Disconnect the shift lock solenoid connector from the shift lock control ECU.

    2. A01A61LC04
      *a

      Component without harness connected

      (Shift Lock Control Solenoid)

      Measure the resistance according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1 (SLS+) - 2 (SLS-) Always 101 to 123 Ω
      3 (E2) - 4 (P) Shift lever in P 10 kΩ or higher
      3 (E2) - 4 (P) Shift lever not in P Below 1 Ω
    3. Apply 12 V battery voltage to the shift lock solenoid and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1 (SLS+)

      Battery negative (-) → Terminal 2 (SLS-)

      Solenoid moves and makes an operating noise

      If the result is not as specified, replace the transmission floor shift assembly.

  3. INSPECT TRANSMISSION CONTROL SWITCH

    B001R9UC13
    *a

    Component without harness connected

    (Transmission Control Switch)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 (IG) - 7 (S) Shift lever in S, "+" or "-" Below 1 Ω
      2 (SFTU) - 5 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
      1 (SFTD) - 5 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
      3 (IG) - 7 (S) Shift lever not in S, "+" or "-" 10 kΩ or higher
      2 (SFTU) - 5 (E) Shift lever in S 10 kΩ or higher
      1 (SFTD) - 5 (E) Shift lever in S 10 kΩ or higher