POWER WINDOW CONTROL SYSTEM Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch

DESCRIPTION

If the manual up and down functions operate normally but the auto up and down functions do not, then the fail-safe mode may be functioning.

If the power window initialization Click here has not been performed, the auto up and down functions will not operate.

Tech Tips

If the pulse sensor built into the power window regulator motor assembly (for driver side) malfunctions, the power window control system enters fail-safe mode. The remote up and down and auto up and down functions cannot be operated during fail-safe mode. However, the power window can be closed by holding the multiplex network master switch assembly at the auto up position, and opened manually by pushing down the multiplex network master switch assembly.

WIRING DIAGRAM

A003YYOE03

INSPECTION PROCEDURE

Note


  • The power window control system uses a LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting Click here. Troubleshoot the power window control system after confirming that the communication system is functioning properly.

  • If the power window regulator motor assembly (for driver side) has been replaced with a new one, initialize the power window control system Click here.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (Master Switch)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Master switch / Data List.

    5. Read the Data List according to the display on the intelligent tester.

      Master Switch (Multiplex Network Master Switch Assembly)
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      D Door P/W Auto SW Driver door power window auto up and down switch signal / ON or OFF

      ON: Driver door power window auto switch operated

      OFF: Driver door power window auto switch not operated

      -
      OK
      On the intelligent tester screen, ON or OFF is displayed accordingly.

    NG
    OK
  2. READ VALUE USING INTELLIGENT TESTER (D-Door Motor)


    1. Enter the following menus: Body / D-Door Motor / Data List.

    2. Read the Data List according to the display on the intelligent tester.

      D-Door Motor (Power Window Regulator Motor Assembly (for Driver Side))
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      D Door P/W Auto SW Driver door power window auto up and down switch signal / ON or OFF

      ON: Driver door power window auto switch operated

      OFF: Driver door power window auto switch not operated

      -
      OK
      On the intelligent tester screen, ON or OFF is displayed accordingly.

    NG
    OK
  3. PERFORM INITIALIZATION (for Driver Side)


    1. Initialize the power window regulator motor assembly (for driver side) Click here.


    NEXT
  4. CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)


    1. Check that the driver side door power window moves when the auto up and down functions of the multiplex network master switch assembly are operated Click here.

      OK
      Driver side auto up and down functions are normal.

    NG
    OK
  5. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY


    1. Replace the multiplex network master switch assembly Click here.


    NEXT
  6. CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)


    1. Check that the driver side door power window moves when the auto up and down functions of the multiplex network master switch assembly are operated Click here.

      OK
      Driver side auto up and down functions are normal.

    NG
    OK