INSPECT EVAPORATOR TEMPERATURE SENSOR
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Evaporator Temperature Sensor) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Allowable Range |
| *e | Temperature (°C (°F)) |
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
If the resistance is not as specified, replace the evaporator temperature sensor.