| DTC Code | DTC Name |
|---|---|
| Power Source Mode does not Change to ON (IG and ACC) |
DESCRIPTION
When the key is in the vehicle and the power switch is pressed, the power management control ECU receives a signal and changes the power source mode.
When the power management control ECU is replaced with a new one and the cable is connected to the negative (-) auxiliary battery terminal, the power source mode changes to on (IG).
When the auxiliary battery cable is disconnected and reconnected, the power source mode returns to the mode it was in before the auxiliary battery cable was disconnected.
INSPECTION PROCEDURE
When using the intelligent tester with the power switch off, perform either of the following: 1) Turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the intelligent tester and vehicle begins, or 2) connect the intelligent tester to the vehicle, select the vehicle type under manual mode, and then enter the following menus:
for Power Source Control: Body / Power Source Control / DTC.
for Entry&Start: Body / Entry&Start / DTC.
Make sure that no DTCs are output. If any DTCs are output, proceed to the Diagnostic Trouble Code Chart (Click here).
The push-button start system uses multiplex communication. First perform the inspections in "How to Proceed with Troubleshooting" to confirm that there are no communication malfunctions before proceeding with troubleshooting (Click here).
If the push-button start system is disabled through the customize function, enable the system before performing troubleshooting (Click here).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After completing repairs, confirm that the problem does not occur.
| Problem Symptom | Data List Item | Active Test Item |
|---|---|---|
| Power source mode does not change to on (IG) or on (ACC) |
|
- |
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (KEY CANCEL SWITCH)
Turn the power switch off.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Entry&Start / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Auto Entry Cancel SW | Push-button start cancel function setting / OFF or ON | Mode status displayed ON: push-button start system canceled OFF: push-button start system not canceled |
The default setting for the push-button start cancel function is OFF. If the customer requests that the push-button start system functions be canceled, the setting can be changed through the customize function (Click here). |
| Result | Proceed to |
|---|---|
| Push-button start cancel function is OFF | A |
| Push-button start cancel function is ON | B |
CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)
Disconnect the H3 and H4 connectors from the power management control ECU.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
READ VALUE USING INTELLIGENT TESTER
Reconnect the L5 and L6 connectors to the power management control ECU.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Key Certification Waiting Timed Out | Key certification error detection/ No or Yes | No: Key certification error not detected Yes: Key certification error detected |
- |
| OK |
|---|
| When more than 1 second elapses after the power switch is turned from off to on (IG), No is displayed in the Data List. |
READ VALUE USING INTELLIGENT TESTER
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Start Switch1 | Start switch 1/ON or OFF | ON: Power switch pushed OFF: Power switch not pushed |
- |
| Start Switch2 | Start switch 2/ON or OFF | ON: Power switch pushed OFF: Power switch not pushed |
- |
| OK |
|---|
| ON (power switch is pushed) and OFF (power switch is not pushed) appear on the screen. |
CHECK POWER MANAGEMENT CONTROL ECU
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Power Supply Condition | Power supply condition/All OFF, ACC ON, IG1 ON, IG2 ON, ST ON | ALL OFF: All relays off ACC ON: ACC relay on IG1 ON: IG1 relay on IG2 ON: IG2 relay on ST ON: ST request signal on |
- |
Measure the voltage while checking the Data List on the intelligent tester.
| Standard Voltage | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CONFIRMATION TEST
Check that the power source mode becomes on (ACC) and on (IG) when the power switch is operated.
| OK |
|---|
| Power source mode becomes on (ACC) and on (IG) when the power switch is operated. |
INSPECT POWER SWITCH
Remove the power switch (Click here).
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Power Switch) |
CHECK HARNESS AND CONNECTOR (POWER SWITCH - POWER MANAGEMENT CONTROL ECU AND BODY GROUND)
Disconnect the H3 and H4 connectors from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CHECK FOR DTC
Enter the following menus: Body / Power Source Control and Entry&Start / DTC.
Check for DTCs.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE POWER MANAGEMENT CONTROL ECUClick here
GO TO DIAGNOSTIC TROUBLE CODE CHART
CHECK RELAY CONTACT SIDE CIRCUIT
USE SIMULATION METHOD TO CHECKClick here
REPLACE POWER SWITCHClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE POWER MANAGEMENT CONTROL ECUClick here
GO TO OTHER FLOW CHART (DTC B2287)Click here
GO TO OTHER FLOW CHART (Room Oscillator does not Recognize Key)Click here
PERFORM CANCELLATION OF PUSH-BUTTON START CANCEL FUNCTIONClick here