| DTC Code | DTC Name |
|---|---|
| B1243 | GSW Terminal Circuit Malfunction |
DESCRIPTION
If the collision door lock release function does not operate normally, or an open or short in the GSW input circuit of the main body ECU (multiplex network body ECU) is detected, DTC B1243 will be stored.
Tech Tips
If DTC B1243 is stored, the speed-sensitive automatic door lock function, shift-linked automatic door lock function, and collision door lock release function will be prohibited.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1243 | A malfunction occurs in the GSW input circuit of the main body ECU (multiplex network body ECU). |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK DTC OUTPUT
Clear the DTCs Click here.
Recheck for DTCs.
| OK |
|---|
| DTC B1243 is not output. |
| NG |
|
CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (GSW VOLTAGE) Click here |
| OK |
|
USE SIMULATION METHOD TO CHECK Click here
CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (GSW VOLTAGE)
Disconnect the cable from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
Disconnect the airbag sensor assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
| *a | Front view of wire harness connector (to Airbag Sensor Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the airbag sensor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
CHECK HARNESS AND CONNECTOR (AIRBAG SENSOR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK) Click here |
| OK |
|
REPLACE AIRBAG SENSOR ASSEMBLY
Disconnect the cable from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
Replace the airbag sensor assembly Click here.
| NEXT |
|
CHECK DTC OUTPUT
Clear the DTCs Click here.
Recheck for DTCs.
| OK |
|---|
| DTC B1243 is not output. |
| NG |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| OK |
|
END (AIRBAG SENSOR ASSEMBLY WAS DEFECTIVE)
CHECK HARNESS AND CONNECTOR (AIRBAG SENSOR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK)
Disconnect the cable from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
Disconnect the airbag sensor assembly connector.
Disconnect the instrument panel junction block connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly Click here.
Remove the main body ECU (multiplex network body ECU).
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) |
- | - |
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here