CAN COMMUNICATION SYSTEM Power Management Control ECU Communication Stop Mode

DESCRIPTION

Detection Item Symptom Trouble Area
Power Management Control ECU Communication Stop Mode
  • "Hybrid Control" and/or "Power Management 1" is not displayed on the Communication Bus Check screen of the intelligent tester.

  • Applies to Power Management Control ECU Communication Stop Mode in DTC Combination Table.


  • Power management control ECU branch line or connector

  • Power source circuit of power management control ECU

  • Power management control ECU

WIRING DIAGRAM

A003YJ6E02
A003YJ6E01

INSPECTION PROCEDURE

Note


  • Turn the power switch off before measuring the resistances between CAN main bus lines and between CAN branch lines.

  • Turn the power switch off before inspecting CAN bus lines for a ground short.

  • After the power switch is turned off, check that the key reminder warning system and light reminder warning system are not operating.

  • Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the power switch, any other switches or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.

Tech Tips


  • Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.

  • Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.

PROCEDURE


  1. CHECK CAN BUS LINE FOR DISCONNECTION (POWER MANAGEMENT CONTROL ECU BRANCH LINE)


    1. Turn the power switch off.

    2. A003ZOXE28
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the H4 power management control ECU connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Value
      H4-25 (CA1H) - H4-24 (CA1L) Power switch off 54 to 69 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL)


    1. Reconnect the H4 power management control ECU connector.

    2. A003WKBE01
      Text in Illustration
      *a

      Component with harness connected

      (Power Management Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Value
      A20-5 (+B1) - Body ground Power switch on (IG) 11 to 14 V
      A19-2 (+B2) - Body ground Power switch on (IG) 11 to 14 V

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (GROUND TERMINAL)


    1. Reconnect the H3 power management control ECU connector.

    2. A003V8WE36
      Text in Illustration
      *a

      Component with harness connected

      (Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Value
      H3-6 (E1) - Body ground Always Below 1 Ω

    NG