WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (EMERGENCY CALL SWITCH ILLUMINATION POWER SOURCE - BODY GROUND)
| *a | Front view of wire harness connector (to Map Light Assembly) |
Disconnect the T6 map light assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (MAP LIGHT ASSEMBLY - COMBINATION METER ASSEMBLY)
Disconnect the T6 map light assembly connector.
Disconnect the H19 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT MAP LIGHT ASSEMBLY
Disconnect the T6 map light assembly connector.
Connect 4 1.5 V dry-cell batteries in series.
| *a | Component without harness connected (Map Light Assembly) |
Connect the positive lead from the batteries to terminal T6-7 (ILL), and the negative lead to terminal T6-4 (LILL) of the map light assembly connector.
Check if the illumination for the emergency call switch comes on.
| OK |
|---|
| Illumination for the emergency call switch comes on. |
| NG |
|
REPLACE MAP LIGHT ASSEMBLY Click here |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here