TELEMATICS TRANSCEIVER
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H145-1 (+B) - H145-4 (E) | LG - W-B | Battery | Power switch off | 11 to 14 V |
| H145-2 (SPI+) - H145-4 (E) | LG - W-B | Sound signal | Audio system playing | A waveform synchronized with sounds is output |
| H145-3 (SPI-) - H145-4 (E) | L - W-B | Sound signal | Audio system playing | A waveform synchronized with sounds is output |
| H145-4 (E) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| H145-5 (SPO+) - H145-4 (E) | G - W-B | Sound signal | Emergency call mode | A waveform synchronized with the received voice is output. |
| H145-6 (SPO-) - H145-4 (E) | BR - W-B | Sound signal | Emergency call mode | A waveform synchronized with the received voice is output. |
| H145-7 (IG2) - H145-4 (E) | B - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| H145-8 (ACC) - H145-4 (E) | B - W-B | Accessory (ON) | Power switch on (ACC) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| H145-9 (SLED) - H145-4 (E) | GR - W-B | Emergency call switch illumination power supply | Power switch on (ACC) | 5 to 8 V |
| Power switch off | Below 1 V | |||
| H145-11 (IND1) - H145-4 (E) | B - W-B | Emergency call switch red indicator illumination signal | For 5 seconds after turning the power switch on (ACC) | 1 to 8.5 V |
| Power switch off | Below 1 V | |||
| H145-12 (IND2) - H145-4 (E) | GR - W-B | Emergency call switch green indicator illumination signal | For 5 seconds after turning the power switch on (ACC) | 1 to 8.5 V |
| Power switch off | Below 1 V | |||
| H145-13 (BBI-) - H145-4 (E) | R - W-B | Mayday battery power supply | - | - |
| H145-17 (MUTE) - H145-4 (E) | L - W-B | MUTE Signal | Audio system playing | Below 1 V |
| Emergency call mode | 3.5 V or higher | |||
| H145-18 (MCO+) - H145-4 (E) | G - W-B | Microphone voice signal | See "Microphone&Voice Recognition Check" Click here |
- |
| H145-19 (MCO-) - H145-4 (E) | R - W-B | Microphone voice signal | See "Microphone&Voice Recognition Check" Click here |
- |
| H145-20 (CTR1) - H145-4 (E) | L - W-B | Mayday battery control line | - | - |
| H145-21 (CTR2) - H145-4 (E) | G - W-B | Mayday battery control line | - | - |
| H145-24 (GSW) - H145-4 (E) | LG - W-B | Airbag deployment signal | Power switch on (IG) | Pulse generation (Refer to waveform 1) |
| H145-26 (SIG-) - H145-4 (E) | P - W-B | Ground | Always | Below 1 V |
| H145-27 (SIG1) - H145-26 (SIG-) | L - P | Emergency call switch button condition signal | Emergency call switch button not pressed | 1.7 V |
| Emergency call switch button pressed | 0.7 V | |||
| H145-30 (BBI+) - H145-4 (E) | B - W-B | Mayday Battery Power Supply | - | - |
| H145-32 (SGND) - H145-4 (E) | Shield - W-B | Shield ground | Always | Below 1 V |
| H145-33 (MCVD) - H145-4 (E) | B - W-B | Telephone microphone assembly power supply | Power switch on (ACC) | 4 to 6 V |
| Power switch off | Below 1 V | |||
| H145-34 (MCI+) - H145-4 (E) | W - W-B | Microphone voice signal | See "Microphone&Voice Recognition Check" Click here |
- |
| H145-35 (MCI-) - H145-4 (E) | R - W-B | Microphone voice signal | See "Microphone&Voice Recognition Check" Click here |
- |
| H133-1-1 (USB-) | - | USB communication line | - | - |
| H133-1-2 (USB+) | - | USB communication line | - | - |
| H133-1-3 (USBS) - Body ground | Shield - Body ground | Shield ground | Always | Below 1 V |
| H133-2 (USBG) - Body ground | W - Body ground | Shield ground | Always | Below 1 V |
| H133-3 (VOT+) - H145-4 (E) | G - W-B | Receive voice signal | Receiving a call while using the operator service | A waveform synchronized with the received voice is output. |
| H133-4 (USBV) - H145-4 (E) | W - W-B | Telephone microphone assembly power supply | Power switch on (ACC) | 4.5 to 5.25 V |
| Power switch off | Below 1 V | |||
| H133-5 (VOT-) - H145-4 (E) | B - W-B | Receive voice signal | Receiving a call while using the operator service | A waveform synchronized with the received voice is output. |
| H133-6 (VOR-) - H145-4 (E) | R - W-B | Sent voice signal | Calling while using the operator service | A waveform synchronized with the sent voice is output |
| H133-7 (VOR+) - H145-4 (E) | W - W-B | Sent voice signal | Calling while using the operator service | A waveform synchronized with the sent voice is output |
Reference (Oscilloscope waveform):
Waveform 1
| Item | Condition |
|---|---|
| Tester Connection | H145-24 (GSW) - H145-4 (E) |
| Tool setting | 5.0 V/DIV., 20 ms/DIV. |
| Vehicle condition | Power switch on (IG) |