RELAY ON-VEHICLE INSPECTION


  1. INSPECT DIM RELAY


    1. A003V6CE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω
      3 - 4 Voltage is not applied between terminals 1 and 2 Below 1 Ω
      3 - 4 Voltage is applied between terminals 1 and 2 10 kΩ or higher

      If the result is not as specified, replace the DIM relay.

  2. INSPECT DRL RELAY


    1. A003ZUHE02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the DRL relay.

  3. INSPECT RR FOG RELAY


    1. A003ZUHE02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the RR FOG relay.