HAZARD WARNING SWITCH INSPECTION


  1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. A003YLGE01
      Text in Illustration
      *a

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      6 (HAZ) - 3 (GND) Hazard warning switch off 10 kΩ or higher
      Hazard warning switch on Below 1 Ω

      If the result is not as specified, replace the hazard warning signal switch assembly.