HYBRID / BATTERY CONTROL SERVICE DATA

Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard value (for brand-new cap)

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)

Minimum standard value (for used cap)

94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition

IGCT relay

Resistance

3 - 5

10 kΩ or higher

(No auxiliary battery voltage is applied across terminals 1 and 2)

3 - 5

Below 1 Ω

(Auxiliary battery voltage is applied across terminals 1 and 2)

Hybrid Battery Junction Block Assembly

SMRB

Resistance

4 (SMRB) - 2 (GND) 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))

SMRG

Resistance

1 (SMRG) - 2 (GND) 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))

SMRP

Resistance

3 (SMRP) - 2 (GND) 112 to 274 Ω (at -40°C (-40°F) to 80°C (176°F))

Precharge

resistor

- 28.5 to 31.5 Ω
Electric vehicle fuse - Below 1 Ω
Service plug grip
Service plug grip Always Below 1 Ω
Combination Switch Assembly
EV switch H72-3 (S) - H72-14 (E)

Below 1 Ω

(EV switch being pushed and held)

10 kΩ or higher

(EV switch not operated)

SPORT mode switch H72-6 (PWR) - H72-14 (E)

Below 1 Ω

(Mode switch being turned and held at SPORT position)

10 kΩ or higher

(Mode switch not turned)

ECO mode switch H72-5 (ECO) - H72-13 (E)

Below 1 Ω

(Mode switch being turned and held at ECO position)

10 kΩ or higher

(Mode switch not turned)

NORMAL mode switch H72-4 (NORM) - H72-14 (E)

Below 1 Ω

Mode switch being pushed and held at NORMAL position

10 kΩ or higher

Mode switch not pushed

seat heater switch

3 (RV) - 4 (SW)

LH Side

0.28 to 0.42 kΩ

(Off)

0.28 to 0.42 kΩ

(On (Min.))

2.72 to 4.08 kΩ

(On (Max.))

1 (REL1) - 6 (SW)

0.28 to 0.42 kΩ

(Off)

0.28 to 0.42 kΩ

(On (Min.))

2.72 to 4.08 kΩ

(On (Max.))