WATER PUMP WITH MOTOR INSTALLATION


  1. INSTALL INVERTER WATER PUMP ASSEMBLY


    1. Install the inverter water pump assembly and water pump bracket with the 3 bolts.

      Torque:
      6.1 N*m  { 62 kgf*cm, 54 in.*lbf }

      Note

      Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.

    2. A003W6LE01
      Text in Illustration
      *a Front Side
      *b Matchmark (Green)
      *c Matchmark (White)

      Connect the 2 water hose and connector.

      Note


      • Make sure that the clip is positioned as shown in the illustration.

      • Make sure to align the matchmarks of the hoses with the ribs of the inverter water pump assembly.

  2. INSTALL INVERTER TRAY BRACKET


    1. A003XZQE01

      Position the inverter tray bracket as shown in the illustration.

    2. Temporarily install bolt B to the inverter tray bracket.

    3. Tighten the 5 bolts to the inverter tray bracket in the order bolt A, bolt C, bolt D, bolt E and bolt B.

      Torque:
      18 N*m  { 184 kgf*cm, 13 ft.*lbf }
    4. Connect the 2 clamps to the inverter tray bracket.

  3. INSTALL INVERTER RESERVE TANK ASSEMBLY


    1. A003V8FE01

      Temporarily install bolt A to the inverter reserve tank assembly.

    2. Tighten the 2 bolts to the inverter reserve tank assembly in the order bolt B and bolt A.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
  4. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here

  5. ADD COOLANT (for Inverter)

    Note


    • Do not reuse the drained coolant because it may contain foreign objects.

    • If the vehicle is driven with air in the inverter cooling system, damage may occur and the following DTCs may be stored.

      DTC No. Detection Item
      P0A01-726 Motor Electronics Coolant Temperature Sensor Circuit Range / Performance
      P0A04-725 Motor Electronics Coolant Temperature Sensor Circuit Intermittent
      P0A08-264 DC / DC Converter Status Circuit
      P0A78-284 Drive Motor "A" Inverter Performance
      P0A78-286 Drive Motor "A" Inverter Performance
      P0A7A-322 Generator Inverter Performance
      P0A7A-324 Generator Inverter Performance
      P0A93-346 Inverter Cooling System Performance
      P0A94-553 DC / DC Converter Performance
      P0A94-557 DC / DC Converter Performance
      P0AEE-277 Motor Inverter Temperature Sensor "A" Circuit Range / Performance
      P0AF1-276 Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent / Erratic
      P0BCD-315 Generator Inverter Temperature Sensor Circuit Range / Performance
      P0BD0-314 Generator Inverter Temperature Sensor Circuit Intermittent / Erratic
      P0C39-626 DC / DC Converter Temperature Sensor "A" Range / Performance
      P0C3C-625 DC / DC Converter Temperature Sensor "A" Intermittent / Erratic
      P0C3E-628 DC / DC Converter Temperature Sensor "B" Range / Performance
      P0C41-627 DC / DC Converter Temperature Sensor "B" Intermittent / Erratic
      P0C73-776 Motor Electronics Coolant Pump "A" Control Performance

    1. A003W8W

      Slowly pour coolant into the reserve tank until it reaches the full line.

      Coolant quantity
      2.1 liters (2.2 US qts, 1.8 Imp. qts.)
    2. When using the intelligent tester:


      1. Connect the intelligent tester to the DLC3.

      2. Turn the power switch on (IG).

      3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

      4. Keep the coolant at the full line in the reserve tank to compensate for the drop in coolant level when the air bleeds.

        Standard
        Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump assembly becomes smaller and the circulation of coolant in the reserve tank improves.

        Tech Tips

        Loud noise made by the inverter water pump assembly and poor circulation of coolant in the reserve tank indicates that there is air in the cooling system.

    3. When not using the intelligent tester:


      1. Turn the power switch on (READY). [*1]

      2. Turn the power switch off and add coolant to the full line because the coolant level drops as the air bleeds. [*2]

        Note


        • Be sure to turn the power switch off before adding SLLC.

        • Do not work on the components in the engine compartment while the vehicle is in the READY-on state because the engine is in intermittent operation.

      3. Repeat steps [*1] and [*2] until air bleeding from the cooling system is completed.

        Standard
        Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump assembly becomes smaller and the circulation of coolant in the reserve tank improves.

        Tech Tips

        Loud noise made by the inverter water pump assembly and poor circulation of coolant in the reserve tank indicates that there is air in the cooling system.

    4. After the air is completely bled from the cooling system, tighten the reserve tank cap.

    5. A003W8W

      Add coolant to the full line of the reserve tank.

  6. INSPECT FOR COOLANT LEAK (for Inverter)


    1. Remove the reserve tank cap.

      CAUTION:

      To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.

    2. A003V28

      Install a radiator cap tester.

    3. Pump the radiator cap tester to 122 kPa (1.2 kgf/ cm2, 18 psi), and then check that the pressure does not drop.

      Tech Tips

      If the pressure drops, check the hoses, radiator, inverter water pump assembly, inverter with converter, and hybrid vehicle transaxle assembly for leaks.

    4. Reinstall the reserve tank cap.

  7. INSTALL NO. 1 ENGINE UNDER COVER