REMOVE NO. 1 ENGINE UNDER COVER
DRAIN COOLANT (for Inverter)
Note
Do not reuse the drained coolant because it may contain foreign objects.
Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.
Remove the reserve tank cap.
CAUTION:
To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.
Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.
CAUTION:
Use caution when handling coolant immediately after driving or in summer because it may be hot.
Install the plug with a new gasket.
REMOVE INVERTER WITH CONVERTER ASSEMBLY
REMOVE INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts and separate the inverter reserve tank assembly.
REMOVE INVERTER TRAY BRACKET
Separate the 2 clamps.
Remove the 5 bolts and inverter tray bracket.
REMOVE INVERTER WATER PUMP ASSEMBLY
Disconnect the 2 water hose and connector.
Remove the 3 bolts and the inverter water pump assembly with the water pump bracket.